Technical documentation

Article 37 of the EHDS regulation requires a manufacturer to draw up technical documentation before an EHR system is placed on the market or put into service, and to keep it up to date. Article 37(2) says it must contain at least the elements of Annex III, and a reference to the results of the European digital testing environment of Article 40. From 11 December 2027 the same documentation carries the content of CRA Annex VII (CRA Art. 31(3) as EHDS Article 104 replaces it).

Cadasto B.V., the manufacturer of each tagged FerroEHR release, keeps that documentation in the repository, in docs/technical-documentation/: one file per Annex III element and per CRA Annex VII point that adds one, each linking its evidence. The tree as it stands at a release tag is that release’s documentation. This page maps each Annex III element to its file and to the published material it cites. It covers FerroEHR’s part of the EHR system, the logging component and the system-level requirements; FerroBRIDGE documents the interoperability component.

Warning

The documentation is incomplete: element 3 and element 6 cannot be written yet, and element 4 lacks the testing-environment results. No EU declaration of conformity exists. An “Available” row below means the material the element asks for is written and cited from the tree, not that any authority has examined it.

Regulation (EU) 2025/327 of the European Parliament and of the Council of 11 February 2025 on the European Health Data Space and amending Directive 2011/24/EU and Regulation (EU) 2024/2847, OJ L series, 2025/327, 5.3.2025. Read on 2026-10-06; the regulation governs and the summaries here are this project’s paraphrase.

Annex III, element by element

1. A detailed description of the EHR system

Documented in annex-iii-1-description.md.

#ElementStateMaterialNotes
1(a)Intended purpose, date and version.Availablewhat existsFerroEHR’s part of the statement of intended purpose is versioned with the book, which is frozen per release; the version and release date are each release’s tag and changelog heading. The statement for the EHR system as a whole is in the FerroHEALTH book (https://ferrohealth.eu/docs/ehds/intended-purpose.html).
1(b)The categories of personal electronic health data it processes.Availablewhat exists—
1(c)How it interacts with hardware or software that is not part of it.Availablewhat exists—
1(d)Versions of relevant software or firmware, and update requirements.Availablewhat exists—
1(e)Every form in which it is placed on the market or put into service.Availablewhat exists—
1(f)The hardware it is intended to run on.Partialwhat existsThe instructions for use name the platforms, the chart’s resource defaults and the database; the measured deployment classes state the environment each ran on. No minimum hardware specification is published.
1(g)The system architecture, and how the components integrate.Availablewhat exists—
1(h)Technical specifications, variants, configurations.Availablewhat exists—
1(i)A description of every change through the lifecycle.Availablewhat existsThe changelog of every release, and the revision table of the documentation tree.
1(j)Instructions for use and, where applicable, for installation.Availablewhat exists—

2. The system in place to evaluate the EHR system’s performance

Documented in annex-iii-2-performance-evaluation.md.

#ElementStateMaterialNotes
2Where applicable, how performance is evaluated.Availablewhat existsPerformance is measured by an independent instrument in open-loop, coordinated-omission-free runs, and the records are committed.

3. References to the common specifications used

Documented in annex-iii-3-common-specifications.md.

#ElementStateMaterialNotes
3Common specifications under Article 36 against which conformity is declared.Missing—The implementing acts that set the Article 36 common specifications have not been adopted. Nothing can reference them yet.

4. Verification and validation results

Documented in annex-iii-4-verification-and-validation.md.

#ElementStateMaterialNotes
4Results and critical analyses of the tests demonstrating conformity.Partialwhat existsThe openEHR conformance record and the hazard log’s named tests are committed. They show conformity to the openEHR specifications and the controls of the logging component, which is a different claim from conformity to Annex II; the European digital testing environment of Article 40, whose results Article 37(2) asks for, is not published.

5. A copy of the information sheet

Documented in annex-iii-5-information-sheet.md.

#ElementStateMaterialNotes
5The information sheet required by Article 38.Availablewhat existsPublished with the book of each release and attached to each GitHub release.

6. A copy of the EU declaration of conformity

Documented in annex-iii-6-declaration-of-conformity.md.

#ElementStateMaterialNotes
6The declaration required by Article 39.Missing—No declaration has been drawn up: the Article 36 common specifications and the Article 40 testing environment it would rest on are not available.

What CRA Annex VII adds

CRA Annex VII asks for four things Annex III does not, each with its own file in the tree: the design, development and vulnerability-handling processes with the software bills of materials (point 2), the cybersecurity risk assessment (point 3), the information taken into account to set the support period (point 4), and the standards applied or the solutions adopted in their place (point 5). The hazard log is the EHDS-side assessment of the logging component, which CRA Art. 13(4), as EHDS Article 104 amends it, lets the cybersecurity risk assessment be part of.

Test evidence

Element 4 asks for the results of the verification and validation tests. What exists is the openEHR conformance record (an independent instrument’s runs against a composed deployment, with the results, verdicts and the statement committed under docs/conformance/ and published on the conformance pages) and the tests the hazard log names for each control of the logging component.

The conformance record demonstrates conformity to the openEHR specifications. Conformity to Annex II is a different claim against a different yardstick. The European digital testing environment of Article 40, whose results Article 37(2) asks the documentation to reference, is not published; running it is tracked in #3620.

Declaration of conformity

Article 39 requires an EU declaration of conformity stating that the essential requirements of Annex II are met, and Annex IV sets out what it contains, including the common specifications applied and the result of the Article 40 testing environment. No declaration has been drawn up. The common specifications of Article 36 have not been adopted, the testing environment is not published, and the exchange format the interoperability component must carry waits on implementing acts under Article 15(1). Chapter III applies to EHR systems from 26 March 2029 (Article 105).

When a declaration is drawn up, Cadasto B.V. draws it up for the EHR system, FerroEHR and FerroBRIDGE together, as one declaration for the EHDS and the CRA. It is published online for each release it covers, for at least ten years (Article 39(4)), and kept with the documentation for ten years after the system covered is placed on the market (Article 30(3)).

Keeping it current, keeping it for ten years

  • Change control (Article 30(2)). A release whose changes touch a module of the logging component updates the documentation tree in the same release, and the release procedure refuses the release otherwise.
  • Retention (Article 30(3)). The tree is part of the signed release tag, which cannot be deleted or moved, and of the source archive each release deposits with Zenodo; the book pages it cites are frozen with each release at /docs/vX.Y.Z/.
  • Translation (Article 37(3) and (4)). The documentation is written in English. A market surveillance authority that asks, with reasons, for a translation of parts of it into an official language of its Member State writes to info@cadasto.com, and Cadasto B.V. provides the translation within 30 days of the request, or sooner where a serious and immediate risk justifies it.